The RMP60 inspection probe is the first to use frequency
hopping spread spectrum (FHSS) transmission and offers
rapid part set-up and part verification on machining centres of
all sizes. It is paired with the RMI, a combined transmitter and
receiver unit.
The RMP60's unique transmission system does not have a
dedicated radio channel. Instead, the probe and receiver "hop"
together through a sequence of frequencies.
RMP60
PRINCIPAL APPLICATION Workpiece measurement and job set-up on medium to large horizontal, vertical
and gantry machining centres, 5-axis machines, twin spindle machines and
vertical turret lathes.
TERRITORY EU, USA, Japan, Canada, Switzerland, Australia, New Zealand, Russia,
Israel and China.
TRANSMISSION TYPE† Frequency hopping spread spectrum radio (FHSS)
OPERATING RANGE Up to 15 m (49.21 ft)
NOMINAL FREQUENCY 2.402 - 2.481 GHz
TURN ON METHOD Radio 'M' code, spin, shank switch
TURN OFF METHOD Radio 'M' code, time out, spin, shank switch
SENSE DIRECTIONS Omni-directional: ±X, ±Y, +Z
UNI-DIRECTIONAL REPEATABILITY 1.0 µm (0.00004 in)
MAX (2s) AT STYLUS TIP‡
WEIGHT 901 g (32 oz)
TRIGGER FORCE
XY plane - lowest force 0.75 N (75 gf) 2.64 ozf
XY plane - highest force 1.40 N (140 gf) 4.92 ozf
+Z axis 5.30 N (530 gf) 18.69 ozf
MAXIMUM ACCELERATION 150 m/s2
STYLUS OVERTRAVEL
XY plane ±18°
+Z direction 11 mm (0.43 in)
MAX SPIN SPEED 1000 rev/min
STANDARD STYLI LENGTHS 50 mm (1.97 in), 100 mm (3.94 in)
RECOMMENDED MAX STYLUS LENGTH 150 mm (5.90 in) NOTE: Longer styli can be used - contact Renishaw.
BATTERY TYPE AND LIFE 2 × AA 1.5 V alkaline 2 × AA 3.6 V lithium thionyl chloride (alternative)
Stand by 650 days max. 1300 days max.
5 % usage 100 days max. 200 days max.
Continuous life 140 hours max. 280 hours max.
SEALING IPX8
SHANKS§ Various
COMPATIBLE INTERFACE¥ RMI
† See Transmission Systems section for more details. ‡ Test conditions stylus length: 50 mm 1.97 in
§ See Shanks section for more details. stylus velocity: 480 mm/min 18.90 in/min
¥ See Interfaces section for more details stylus force: factory settings